[2023] Valid 350-601 test answers & Cisco 350-601 exam pdf
Verified 350-601 dumps Q&As - Pass Guarantee or Full Refund
The Cisco 350-601 (Implementing Cisco Data Center Core Technologies (350-601 DCCOR)) certification exam is a comprehensive exam that evaluates a candidate's knowledge and skills in implementing core data center technologies. This exam is designed to test a candidate's proficiency in implementing data center technologies such as network, storage, compute, automation, and security. If you are looking to enhance your career prospects in the field of data center technologies, then the Cisco 350-601 certification exam is a great option to consider.
The Cisco 350-601 exam is an important certification for IT professionals who work with data center technologies. The certification demonstrates that the candidate has the knowledge and skills needed to design, implement, and manage data center technologies using Cisco products and solutions. The certification is recognized by employers around the world and can help IT professionals advance their careers in the field of data center technologies.
NEW QUESTION # 166
Refer to the exhibit.
Which command needs to be added to the line starling with the "file" keyword to have the generated running-config file with the name 'fusion-config_' and current date?
- A. ('fusion-config_ + date')
- B. ('fusion-config_') + date
- C. string(('fusion-config_') + date)
- D. str.('fusion-config_') + date
Answer: D
NEW QUESTION # 167
An engineer is implementing NetFlow on a Cisco Nexus 7000 Series Switch. Drag and drop the NetFlow commands from the left into the correct order they must be entered on the right.
Answer:
Explanation:
Explanation
1- feature netflow
2- flow exporter
3- flow monitor
4- interface<interface>
NEW QUESTION # 168
An engineer is implementing security on the Cisco MDS 9000 switch. Drag drop the descriptions from the left onto the correct security features on the right.
Answer:
Explanation:
NEW QUESTION # 169
Which component is upgraded by using an EPLD upgrade on a Cisco Nexus 9000 Series Switch?
- A. BIOS
- B. dual-homed fabric extenders
- C. field-programmable gate arrays
- D. ISSU of the NX-OS version
Answer: C
NEW QUESTION # 170
An engineer must ensure fabric redundancy when implementing NPV mode on a Cisco MDS 9000 Series Switch.
Which action enables fabric redundancy?
- A. Configure the NPV devices to use an external FLOGI database.
- B. Use TE ports to connect to upstream switches.
- C. Add a port channel to upstream switches.
- D. Connect the NPV devices to multiple upstream switches.
Answer: C
Explanation:
Section: Storage Network
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/5_0/configuration/guides/ int/nxos/cli_interfaces/pc.html
NEW QUESTION # 171
An engineer requires a solution to automate the configuration and deployment of remote network devices for a customer. The engineer must keep these considerations in mind:
* The customer's environment is based on industry-accepted standards and requires a solution that meets these standards.
* The security requirements mandate the use of a secure transport mechanism between the automation software and target devices such as SSH or TLS.
* The solution must be based on a human-readable and easy to parse format such as XML or JSON.
Which solution must be used to meet these requirements?
- A. SNMP
- B. REST API
- C. Ansible
- D. NETCONF
Answer: D
Explanation:
Explanation
https://www.cisco.com/c/en/us/products/collateral/ios-nx-os-software/ios-xe/nb-06-cisco-ios-xe-faq-en.html
NEW QUESTION # 172
A network engineer must determine the cooling requirements for a Cisco UCS C-Series Rack Server. The server with PCIe cards is configured with a fan configuration policy. Which configuration should be used for the fan policy of the server?
- A. Option B
- B. Option C
- C. Option D
- D. Option A
Answer: D
NEW QUESTION # 173
The engineer must configure SPAN on a cisco Nexus 5000 Series switch to get a capture of the traffic from these applications for an in-depth packet analysis. Which two characteristics must be considered? (Choose two.)
- A. SPAN source port can be monitored in multiple SPAN sessions.
- B. Only Ethernet, FC, vFC, port channel port types can be a destination SPAN port.
- C. The Ethernet, FC, vFC, port channel, SAN port channel can be used as SPAN source ports.
- D. The rx/tx option is available for VLAN or VSAN SPAN sessions.
- E. A SPAN source port cannot be a destination SPAN port.
Answer: C,E
Explanation:
https://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/configuration/guide/cli_rel_4_1/Cisco_Nexus_5000_Series_Switch_CLI_Software_Configuration_Guide_chapter50.html
NEW QUESTION # 174
What are two requirements when planning a Cisco HyperFlex All Flash standard cluster installation using three HX240c M5 servers? (Choose Two)
- A. The servers must be discovered, unassociated, and connected to each fabric interconnect.
- B. If the Jumbo MTU option in the HyperFlex installer is enabled, then jumbo frames do not have to be enabled on the upstream switches.
- C. The cluster deployment type must support a mix of HDD and SS
- D. If the Jumbo MTU option in the HyperFlex installer is enabled, then jumbo frames must also be enabled on the upstream switches.
- E. The hypervisors must be installed to Cisco FlexFlash SD cards.
Answer: A,D
Explanation:
https://www.cisco.com/c/en/us/td/docs/hyperconverged_systems/HyperFlex_HX_DataPlatformSoftware/ AdminGuide/3_5/ b_HyperFlexSystems_AdministrationGuide_3_5/b_HyperFlexSystems_AdministrationGuide_3_5_chapter_01111.html
NEW QUESTION # 175
Which behavior defines streaming telemetry as a push model in Cisco devices?
- A. Events and network changes generate telemetry data
- B. JSON encoded telemetry data is transported using the gRPC protocol
- C. The network devices send data in JSON or GPB format to configured endpoints
- D. Monitoring clients are pulling data from the network to see real-time statistics
Answer: A
Explanation:
Explanation
https://developer.cisco.com/docs/ios-xe/#!streaming-telemetry-quick-start-guide/streaming-telemetry
NEW QUESTION # 176
A cisco Nexus 9000 series switch experiences a startup configuration comuption. The engineer must implement a procedure to recover configuration file from the switch. Which command set must be used?
- A. 1. Clear the current configuration of the switch
2. Restart the device.
3. Copy the running configuration to the startup configuration
4. Copy a previously saved configuration file to the running configuration - B. 1. Clear the current configuration of the switch
2. Restart the device.
3. Copy a previously saved configuration file to the running-configuration
4. Copy the running-configuration to the startup configuration. - C. 1. Copy the running-configuration to the startup configuration.
2. Clear the current configuration of the switch.
3. Restart the device.
4. Copy a previously saved configuration file to the running configuration. - D. 1.Restarting device.
2. Copy the running-configuration file to a remote server.
3. Clear the current configuration of the switch.
4. Copy the running configuration to the startup configuration
Answer: B
Explanation:
Explanation
Problems, such as memory corruption, can occur that make it necessary for you to recover your configuration from a backed-up version.
Each time that you enter a copy running-config startup-config command, a binary file is created and the ASCII file is updated. A valid binary configuration file reduces the overall boot time significantly. A binary file cannot be uploaded, but its contents can be used to overwrite the existing startup configuration. The write erase command clears the binary file.
SUMMARY STEPS
1. write erase
2. reload
3. copy configuration-file running-configuration
4. copy running-config startup-config
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/fundamentals/configuration/guide
NEW QUESTION # 177
A network engineer must restore the running configuration on a Cisco Nexus 5000 Series Switch to an existing snapshot called "stable1". The restore procedure should proceed only if no errors occur. Which configuration should be used to accomplish this goal?
- A. rollback checkpoint stable1 best-effort running-config best-effort
- B. rollback running-config checkpoint stable1 best-effort
- C. rollback checkpoint stable1 best-effort running-config atomic
- D. rollback running-config checkpoint stable1 atomic
Answer: D
NEW QUESTION # 178
An engineer must configure a named VSAN when the fabric interconnect is in Fibre Channel switch mode The VSAN must meet these requirements:
* Named VSAN must be called "VSAN 10".
* VSAN ID must be 10.
* FCoE ID must be 20.
* VSAN 10 must be attached to port 2 in slot 1.
Which command set configures a VSAN when the fabric interconnect is in Fibre Channel switch mode?
- A. Option B
- B. Option C
- C. Option D
- D. Option A
Answer: D
NEW QUESTION # 179
An engineer is enabling port security on a Cisco MDS 9000 Series Switch.
Which feature of enabling port security on a Cisco MDS 9000 Series Switch must be considered?
- A. It binds the fabric at the switch level.
- B. It always learns about switches that are logging in.
- C. It authorizes only the configured sWWN to participate in the fabric.
- D. It can be distributed by using Cisco Fabric Services.
Answer: D
NEW QUESTION # 180
A network engineer must implement a telemetry solution to collect real-time structured data in a large-scale network. Drag and drop the actions from the left into the order on the right to implement the solution. Not all actions are used.
Answer:
Explanation:
Explanation
1. set the format and destination to which the data is sent.
2. configure the data to be collected as part of the sensor group.
3. set the subscription between the sensor-group and the destination.
NEW QUESTION # 181
An engineer is configuring VNTag between a virtualized server and a Cisco Nexus 5500 Series switch. Drag and drop the configuration steps from the into the correct order on the right.
Answer:
Explanation:
Explanation
install the virtualization feature set
Enable the virtualization feature set
Configure the port profile
Configure support for VNTag mode on the interface that connects to the server.
Configure the server to support NIV mode
Configure the vNICs of the server
NEW QUESTION # 182
Refer to the exhibit.
What is the result of implementing this configuration?
- A. The timeout value on the TACACS+ server is 10 seconds.
- B. The TACACS+ server uses the type-6 encrypted format.
- C. The switch queries the TACACS+ server by using a clear text PAP login.
- D. The switch queries the TACACS+ server by using an encrypted text PAP login.
Answer: C
NEW QUESTION # 183
......
350-601 Exam Questions – Valid 350-601 Dumps Pdf: https://www.passexamdumps.com/350-601-valid-exam-dumps.html
350-601 PDF Dumps Recently Updated Questions: https://drive.google.com/open?id=1VafVFV1lo-6baf863mwNZteOUkg7XHEn
